Standard configuration:
1. Set cold-hot start, and the system will reach steady operation in a few minutes after starting.
2. With New energy-saving technology, energy consumption is only 75% of the similar products.
3. Gaseous distributors within the adsorbent tower raise the utility of the molecular sieve and reduce the impact of the molecular sieve bed;
4. Ensure most effectively packing the molecular sieve with combination method.
5. Cylinder pressing makes the packed solid sinking visible. The first pressing on the molecular sieve bed yields warning, and the second pressing causes self-locking, to prevent the molecular sieve from pulverizing and bleeding, and to make the system safer and more reliable.
6. Detect nitrogen purity on line, and warn automatically if the gas is of disqualification.
7. The products with fixed and movable structure can be used in different zones of the granary.
8.The sledge block design is convenient for transportation and installation.
Additional intelligent configuration:
1. Provide a PC program conveniently for transmission and storage of real-time operating data;
2. Rs485 communication. Real-time observation can be done in remote offices;
3. Parameters of flowrate, purity, booting time, etc. are displayed digitally. Cues for instrument calibration;
4. Dynamic process is displayed;
5. Multi-functional alarm (purity, fault, maintenance, etc.);
6. Multi-level password protection (level of operator/director/manager), avoids misoperation;
7. Paper-free analog recorder, curve analysis of operating parameters, storage of ten thousands data on site;
8. Quick cold/hot start;
9. Cue of maintenance/protective self-lock;
10. Reset the records of operating time, maintenance time;
11. Count down to maintenance and shutdown;
12. Upgrade and parameter adjustment by users;
13. PDC energy-saving features (Pressure-Difference Control, optional);
14. PID flowrate-steady output (Proportional-Integral-Differential, optional);
15. MODBUS communication, transmitting more than 200 messages;
16. Reserving interfaces of analog quantity of temperature and pressure in the compressor, interfaces of shutdown and fault warning, being convenient for users to monitor the whole system.